MIPS Fortran I/O Problem?

scott at capone.gatech.edu scott at capone.gatech.edu
Fri Jul 28 08:08:26 AEST 1989


I am attempting to install Precsion Visual's TEXTPRO fonts on an 
SGI Iris 4D. Part of the installation involves converting font
files from ascii text format to a binary format.

The binary file is opened as a direct access, unformatted with a 
record length of 480. Each record is basicly 120 integers. 
The last record in the file is not full...there are only about 51
integers in it. On most other systems, the last record gets
padded with zeros...however, on the SGI it gets truncated. 
I even tried adding RECORDTYPE='fixed', which according to the
manual should force padding of incomplete records, with no
luck.

In this situation, the code is fairly readable and I can force it
to pad by filling the arrays it writes with zeros. However, I may
not be so lucky in other parts of the code I am trying to port.

I am niether a FORTRAN jock or very familiar with SGI...thus I am
not sure if the problem is the result of poor code or a bug in the
MIPS compiler. Any and all clues appreciated...

- Scott

-----
This is my signature. There are many like it, but this one is mine.
Scott Holt, Systems Analyst		Internet: scott at prism.gatech.edu