8-Port-Adapter problems under 3003

Christian Motz cmo at softpro.stgt.sub.org
Fri May 3 05:37:21 AEST 1991


Since we updated to 3003, our 8-Port-RS232-Adapter shows a
very strange behaviour: it will pause output randomly for
a random timeframe, typically between 3 and 10 seconds,
rendering it almost completely unusable for terminal or
modem use. Everytime this "pause"-condition occurs, the
following entry is written to the error log:

---------------------------------------------------------------------------
ERROR LABEL:	COM_TEMP_PIO
ERROR ID:	D428042B

Date/Time:       May 02 02:58:30
Sequence Number: 2062
Machine Id:      000021301000
Node Id:         softpro
Error Class:     H
Error Type:      TEMP
Resource Name:   rsdd
Resource Class:  NONE
Resource Type:   NONE
Location:        NONE

Error Description
PIO exception

Failure Causes
0506

	Recommended Actions
	Adapter can be isolated based upon the address being accessed \
and the adapter assignments made at configuration time.
	PERFORM PROBLEM DETERMINATION PROCEDURES

Detail Data
PIO csr register
0000 0000 
PIO dsisr register
0002 679C 
PIO srval register
0000 0000 
PIO dar register
001D 5A44 
ADAPTER CHECK STATUS
2400 0024 
Additional information
01B6 DDFC 
---------------------------------------------------------------------------

What gives? I already opened a PMR (#77394), but it will probably
take the support people some time to get back to me. Is this a
known problem? Is there a workaround for it? I already tried to
replace rsdd with the one from 3002, to no avail ... diag doesn't
think it's a hardware problem, BTW. Any help would be greatly
appreciated.
							Chris.

-- 
SOFTPRO doesn't speak for me, and I do not speak for SOFTPRO. So what?

                              Christian Motz, cmo at softpro.stgt.sub.org