SIGPWR signal in system v

Dave Decot decot at hpcupt1.cup.hp.com
Sat May 11 11:08:27 AEST 1991


In HP-UX, the only system I know that does anything at all with it,
the signal is sent to all processes after a powerfail *recovery*, not
when power is going away.

Dave