Reliability of (Sys V) file systems on power failure

Dick Dunn rcd at ico.isc.com
Tue Sep 25 09:11:48 AEST 1990


art at pilikia.pegasus.com (Art Neilson) writes:
> ...ir at cel.co.uk (ian reid) writes:
> > [ stuff about file system getting hosed when power is cycled
> >   without performing graceful shutdown ... ]

> Every UNIX I have seen behaves in the manner you describe.  If you
> hit the red switch or experience a power outage without performing a
> graceful shutdown, you deserve whatever you get...

Years ago, that was generally true...and it was one of the major objections
to using UNIX in "commercial" systems.  As a result, essentially all
variants of UNIX have had file system changes to "harden" them against
problems caused by power failure.  Damage from a power outage should be
limited to files being written at the time the power went away, and should
be localized (e.g., a frozzed/missing block of data, not an entire file
gone or destroyed).  Going back to the original question:  If you're
seeing major file system damage due to power failures, there's something
wrong that should be fixed.  I'm not just spouting applehood/motherpie; I
haven't seen a file system damaged by power failure in years.  I've even
tried to damage file systems by getting things as busy as I could, then
turning off machines.  (Of course, the T-storm just now gathering over the
hills will probably destroy all my files and prove me to be drastically
wrong.:-)

The software in hardened file systems is pretty good at ensuring that
things get written when they should, as they should, so that fsck can pick
up the pieces.

This leaves some questions about hardware which were brought up in a couple
other postings on this topic.  There are old but unfortunately-not-apocry-
phal stories about disk controllers which would start writing zeros as
power dropped.  That was a hardware bug; if it happened to you nowadays
you'd need to get your disk controller fixed or replaced.  Taking the 386
PCish world in particular, there is no excuse for a controller writing
because of a power failure.

(Detail:  One pin out of a PC power supply is POWER GOOD.  On a low-
voltage condition, the power supply is expected to drop POWER GOOD; the
motherboard logic must use this to drive RESET on the bus.  Bus cards
must honor RESET as an indication of either system start-up or power
failure.  If this doesn't work, you've got a hardware problem.)

> ...If your UNIX box is used for real
> production work, you are quite foolish not to put it on an UPS...

Neilson signs himself from "Bank of Hawaii"--and I'm glad that someone
associated with banking is taking a conservative attitude on system
failure!  I hate to argue against cautiousness, but not all applications
are critical enough to make an UPS worthwhile.  (The cost of an UPS might
be 10-25% of the cost of the rest of the hardware.  They're getting more
affordable, but they're not cheap.)

If you need constant availability of systems, an UPS is essential.  If data
integrity is paramount, an UPS helps but there are other things you need to
do as well.  My point is that file systems and hardware are expected to be
robust enough that you should *not* tolerate power failures corrupting
file systems.
-- 
Dick Dunn     rcd at ico.isc.com -or- ico!rcd       Boulder, CO   (303)449-2870
   ...Worst-case analysis must never begin with "No one would ever want..."