Transparent Print at a remote site via Computone.
jep
jep at pcgbase.UUCP
Tue Oct 31 07:12:16 AEST 1989
If anyone feels like lending a hand with the following problem it would
be greatly appreciated.
I'm trying to get transparent print at a remote site through a couple of
Telebit modems. I'm using a Computone 3.00 IP nports=8.
The support department of Computone says things like
"uh, maybe jump pin 6 to pin 8 and see if that works". Not to helpful!
The host is an Everex 386/20 (Not a step machine) with one serial port and
one computone card. I'm running SCO Xenix 386 V2.3.1
The modem at the host is a Telebit TrailBlazer Plus with the following
configuration.
E0 F1 M1 Q4 T V1 X3 Version BA4.00
S00=001 S01=000 S02=043 S03=013 S04=010 S05=008 S06=002 S07=040 S08=002 S09=006
S10=007 S11=070 S12=050
S45=000 S47=004 S48=001 S49=000
S50=000 S51=254 S52=002 S53=001 S54=003 S55=000 S56=017 S57=019 S58=002 S59=000
S60=000 S61=045 S62=003 S63=001 S64=000 S65=000 S66=001 S67=000 S68=255
S90=000 S91=000 S92=001 S95=000
S100=000 S101=000 S102=000 S104=000
S110=255 S111=255 S112=001
S121=000
N0:
N1:
N2:
N3:
N4:
N5:
N6:
N7:
N8:
N9:
OK
Cable from Computone port 0 (RJ45 8 pin connector)
Computone Modem
CTS 1------4
DTR 2-----20
TD 3------2
GRND4------7
CD 5------8
RD 6------3
RTS 7------5
The ttys file is set as follows
1mttym00
The gettydefs file is as follows
m # B9600 HUPCL # B9600 CS8 SANE HUPCL TAB3 ECHOE IXANY #\r\n@!login: # m
The Devices is as follows.
ACU ttym00 - 1200-9600 dialTBIT
The remote site is a Wyse 60 with a Telebit T1000 in the default settings.
(Hold down reset and power up the modem)
With the TB on the dump serial port remote access works fine. When I put
the modem on the computone port I can't even get a log in.
Recommendations about other intelligent card will be welcome!
Thanks!!!
--
John E. Phillips (904)672-3856
Phillips Consulting Group, Inc.
24 Chippingwood Lane Ormond Beach, FL 32176
uunet!pcgbase!jep attmail!pcgbase!jep Easylink 62909663
More information about the Comp.unix.xenix
mailing list