SCSI Disk Problems with SS1 and 6 disks.
Mike Proicou
proicou at afwl.af.mil
Sat Jan 26 03:55:57 AEST 1991
I'm having problems with the SCSI disks on my Sparcstation 1. I've been
getting SCSI transport errors every so often, which will affect 1 or more
of the drives. This example affects sd4, but it has occurred on sd2, sd3,
sd4, and sd5 as well. I'm running a modified kernel configuration (SunOS
4.1) with 6 disks and 1 Exabyte tape. I haven't been able to correlate
the errors with excessive disk I/O or lack of I/O.
The problem starts with (from /usr/adm/messages):
npbsun vmunix: sd4: SCSI transport failed: reason 'incomplete': retrying command
npbsun last message repeated 14 times
npbsun vmunix: sd4: disk not responding to selection
npbsun vmunix: sd4: disk not responding to selection
npbsun last message repeated 3 times
npbsun vmunix: sd4: disk not responding to selection
npbsun last message repeated 3 times
and eventually the system will panic like so:
panic: iinactive
syncing file systems... panic: iinactive
00000 low-memory static kernel pages
Here's the device printout after the reboot:
sd0 at esp0 target 3 lun 0
sd0: <Quantum ProDrive 105S cyl 974 alt 2 hd 6 sec 35>
sd1 at esp0 target 1 lun 0
sd1: <Quantum ProDrive 105S cyl 974 alt 2 hd 6 sec 35>
sd2 at esp0 target 2 lun 0
sd2: <arte Imprimis Wren VII 94601-12G cyl 1920 alt 2 hd 15 sec 71>
sd3 at esp0 target 0 lun 0
sd3: <CDC Wren IV 94171-344 cyl 1545 alt 2 hd 9 sec 46>
sd4 at esp0 target 4 lun 0
sd4: <arte Imprimis Wren VII 94601-12G cyl 1920 alt 2 hd 15 sec 71>
sd5 at esp0 target 6 lun 0
sd5: <arte Imprimis Wren VII 94601-12G cyl 1920 alt 2 hd 15 sec 71>
st1 at esp0 target 5 lun 0
After the reboot everything is fine until the next episode. So far the
reboots have been necessary (forced on me) about every ten days. Is there
a way to fix this without rebooting?
Any ideas?
Mike Proicou
proicou at npbsun.afwl.af.mil
More information about the Comp.sys.sun
mailing list