How to disconnect idle dialup users?

Robert J. Granvin rjg at umnstat.uucp
Tue Dec 4 03:25:40 AEST 1990


In article <1990Nov29.181905.26620 at hawkmoon.MN.ORG> det at hawkmoon.MN.ORG (Derek E. Terveer) writes:
|kdq at demott.COM (Kevin D. Quitt) writes:
|
|>    If you've a Telebit modem, register S41 can be set in tenths of
|>hours, from 0 (disabled) to 255.  When the timer expires, the modem
|>hangs up the line. 
|
|(I presume you are talking about the trailblazer series of modems)
|Unfortunately, not all of the Telebit modems support this feature.  I have a
|Trailblazer Plus and it does not have register 41.

Trailblazer+'s, if upgraded to ROM revision BC5.10A (probably any 5.x
variety) will have the register available...

Robert J. Granvin                           E/Mail: rjg at umnstat.stat.umn.edu
User Services Specialist                    AT&T:   +1 612 625 9224
School of Statistics
University of Minnesota



More information about the Comp.unix.admin mailing list