keyboard error on VS3100
Johan Vromans
jv at mhres.mh.nl
Tue Sep 19 09:08:57 AEST 1989
I'm running UWS2.1 on a VAXstation3100. The problem I'm going to
describe also occurred under UWS2.0A.
Sometimes when I move the mouse, the system starts generating errors
of the following kind:
----- EVENT INFORMATION -----
EVENT CLASS OPERATIONAL EVENT
OS EVENT TYPE 250. ASCII MSG
SEQUENCE NUMBER 28.
OPERATING SYSTEM ULTRIX 32
OCCURRED/LOGGED ON Tue Sep 12 14:30:59 1989 MET DST
OCCURRED ON SYSTEM squirrel
SYSTEM ID x0A000004 MICROCODE REV = 4.
SYSTYPE REG. x04010002
FIRMWARE REV = 1.
PROCESSOR TYPE KA420
MESSAGE
sm0: smkint: keyboard error, code = b6
These errors are generated that fast, that they overflow the errlog
buffer, which causes the message ERRLOG BUFFER FULL, 1 ERROR(S) MISSED
to appear on the console.
I have also noticed that, on moments like these, the keyboard audible
bell doesn't sound anymore.
Can anyone tell me what the above error means? Especially the line
"sm0: smkint: keyboard error, code = b6" should mean something to
someone.
Any pointers are appreciated.
Johan
--
Johan Vromans jv at mh.nl via internet backbones
Multihouse Automatisering bv uucp: ..!{mcvax,hp4nl}!mh.nl!jv
Doesburgweg 7, 2803 PL Gouda, The Netherlands phone/fax: +31 1820 62944/62500
------------------------ "Arms are made for hugging" -------------------------
More information about the Comp.unix.ultrix