CDC & 753 Xylogics

Eric Pearce eap at bu-it.bu.edu
Fri Apr 21 16:14:13 AEST 1989


dclassen at swift.bcm.tmc.edu (David Classen) says:
>I have read in this news group that this combination ( CDC 1.2 GB ) works
>well.  I have however had a hard time getting mine installed. The problem
>I have is:
>
>My Sun 4/260 crashes with a an eror message of
>
>	    spurious VME interupt at processor level 5 VME level
>            3, VME vector 0xffffffff
>
>this happens when I try to tar one file system to another or when I run
>suninstall and it's trying to load the usr partition.

We have 4/280 that prints that message out every 10-15 minutes or so, but
it doesn't crash.  I always thought it had something to do with having a
second ethernet interface, since it's usually followed by the the famous
"ie1: spurious interrupt" message.  We have a Xylogics 451, a SCSI 1/4"
tape, a 32 meg memory card, an ALM-2 and a TAAC board.  Field service gave
the generic "it's fixed in the next rev" line, but I've heard it could be
caused by the VME to Multibus adapter cards used by ie1 and the 451.  The
rate of the error messages does seem to increase when the network
interface is used, such as during a remote dump.  We also tried upgrading
to the newest rev cpu (rev 14?) with no change.  I would assume they would
pay more attention to you if it actually crashed your system, instead of
just wasting console paper.  

  -e

 Eric Pearce                                   ARPANET eap at bu-it.bu.edu
 Boston University Information Technology      CSNET   eap%bu-it at bu-cs
 111 Cummington Street                         JNET    jnet%"ep at buenga" 
 Boston MA 02215                               UUCP    !harvard!bu-cs!bu-it!eap 
 617-353-2780 voice  617-353-6260 fax          BITNET  ep at buenga



More information about the Comp.sys.sun mailing list